Part Number Hot Search : 
MC332 LT551 BFP19307 R48D05 TDA1518B JANTXV1 P4500EC VNH5019
Product Description
Full Text Search
 

To Download MSO8000 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Agilent Technologies Infiniium MSO8000 and MSO9000 Series N5433A FPGA Dynamic Probe for Altera
Data Sheet
The challenge
You rely on the insight a MSO (mixed-signal oscilloscope) provides to understand the behavior of your FPGA in the context of the surrounding system. Design engineers typically take advantage of the programmability of the FPGA to route internal nodes to a small number of physical pins for debugging. While this approach is very useful, it has significant limitations. * Since pins on the FPGA are typically an expensive resource, there are a relatively small number available for debug. This limits internal visibility (i.e. one pin is required for each internal signal to be probed). * When you need to access different internal signals, you must change your design to route these signals to the available pins. This can be time consuming and can affect the timing of your FPGA design.
Figure 1. FPGA dynamic probe for Altera used in conjunction with an Agilent MSO provides an effective solution for simple through complex debugging of systems incorporating Altera FPGAs.
* Finally, the process required to map the signal names from your FPGA design to the MSO digital channel labels is manual and tedious. When new signals are routed
out, you need to manually update these signal names on the MSO, which takes additional time and is a potential source of confusing errors.
Debug your FPGAs faster and more effectively with a MSO
FPGA dynamic probe lets you: View internal activity - With the digital channels on your MSO, you are normally limited to measuring signals at the periphery of the FPGA. With the FPGA dynamic probe, you can now access signals internal to the FPGA. You can measure up to 256 internal signals for each external pin dedicated to debug, unlocking visibility into your design that you never had before. Make multiple measurements in seconds - Moving probe points internal to an FPGA used to be time consuming. Now, in less than a second, you can easily measure different sets of internal signals without design changes. FPGA timing stays constant when you select new sets of internal signals for probing. Leverage the work you did in your design environment - The FPGA dynamic probe maps internal signal names from your FPGA design tool to your Agilent MSO. Eliminate unintentional mistakes and save hours of time with this automatic setup of signal and bus names on your MSO.
Probe outputs on FPGA pins Board FPGA
LAI
SW application supported by all Infiniium MSOs.
Parallel or USB JTAG
Altera programming hardware
Figure 2. The FPGA dynamic probe requires Altera's Quartus II design software with its LAI (logic analyzer interface) and Altera programming hardware setup. The Quartus II (ver. 6.0 or higher) LAI allows you to create and insert a debug core that interacts with the FPGA dynamic probe application on your MSO. The FPGA dynamic probe controls which group of internal signals to measure via the Altera programming hardware connected to the JTAG port of the FPGA.
1-256
Selection MUX
1-256 1-256
1-256
To FPGA pins
1-256
Change signal bank selection via JTAG
JTAG
Figure 3: Access up to 256 internal signals for each debug pin. Signal banks all have identical width (1 to 256 signals wide) determined by the number of device pins you devote for debug. MSO8000 series can acquire up to 16 signals using digital channels. Each pin provides sequential access to one signal from every input bank.
2
Select
A quick tour of the application
Design step 1: Configure the logic analyzer interface file and core parameters You need to create a Altera LAI file with MSO in Quartus II. This file defines the interface that builds a connection between the internal FPGA signals and the MSO digital channels. You can then configure the core parameters, which include number of pins, number of signal banks, the type of measurement (state or timing), clock and the power-up state.
Design step 2: Map the Altera LAI core outputs to available I/O pins Use Pin Planner in Quartus II to assign physical pin locations for the LAI.
3
A quick tour of the application (continued)
Design step 3: Assign LAI bank parameters Assign internal signals to each bank in the LAI after you have specified the number of banks to use in the core parameters. Find the signals you want to acquire with the Node Finder and assign them to the banks. With the LAI core fully configured and instantiated into your FPGA design, you're ready to compile your design to create the device programming file (.sof). Then, to make measurements you'll move to the Agilent MSO with FPGA dynamic probe software.
Activate FPGA dynamic probe for Altera The FPGA dynamic probe application allows you to control the LAI and set up the MSO for the desired measurements.
4
A quick tour of the application (continued)
Measurement setup step 1: Establish a connection between the MSO and the LAI The FPGA dynamic probe application establishes a connection between the MSO and the FPGA via a JTAG cable. It also determines what devices are on the JTAG scan chain and lets you pick the one with which you wish to communicate.
Measurement setup step 2: Configure the device and import signal names If needed, you can configure the device with the SRAM object file (.sof) that includes the logic analyzer interface file. The FPGA dynamic probe application reads a .lai file produced by Quartus II. The names of signals you measure will now automatically appear in the label names on your Agilent MSO.
Measurement setup step 3: Map FPGA pins Select your probe type and easily provide the information needed for the MSO to automatically track names of signals routed through the LAI file.
5
A quick tour of the application (continued)
Setup complete: Make measurements Quickly change which signal bank is routed to the MSO. A single mouse click tells the LAI core to switch to the newly specified signal bank without any impact to the timing of your design. To make measurements throughout your FPGA, change signal banks as often as needed. With each new selection of a signal bank, FPGA Dynamic Probe updates new signal names from your design to the MSO. User-definable signal bank names make it straight forward to select a part of your design to measure.
Make state measurements with your MSO MSOs incorporate some logic analysis state capabilities useful for making FPGA measurements. Using pattern trigger, setup a state trigger on LAI clock output edge and desired digital pattern. After acquiring the data, use the post-processing "State clock" feature to transform the timing waveforms into state waveforms. Valid states are shown and invalid states are filtered. Any of the 16 digital channels or any of the analog channels can be set as the state clock. Using an analog channel state clock allows you to retain all 16 digital channels for bus measurement.
Correlate internal FPGA activity with external measurements View internal FPGA activity and time-correlate internal FPGA measurements with external analog and digital events in the surrounding system. FPGA Dynamic Probe unlocks the power of the MSO for system-level debug with FPGAs.
6
Agilent N5433A specifications and characteristics
Supported oscilloscopes Standalone oscilloscopes MSO Digital Channels Bus groupings Triggering capabilities Supported Altera FPGA families Supported Altera cables (required) Supported probing mechanisms All Infiniium 8000 and 9000 Series MSOs. 16 Up to 4, each with 16 character labels Determined by MSO, all have state triggering All families that the Altera LAI core supports including, Stratix IV, Stratix III, Stratix II and Stratix, Cyclone III, Cyclone II and Cyclone, Arria II and Arria. Altera USB Blaster or ByteBlaster Soft touch (34-channel and 17-channel), Mictor, Samtec, Flying lead, Infiniium MSOs come standard with a 40 pin probe cable and flying leads.
Altera LAI characteristics Number of output signals Signal banks Modes Compatible software Altera Quartus II 6.0 or greater Infiniium 8000 version 5.2 or greater. Infiniium 9000 version 2.0 or greater. User definable: 1 to 256 signals in 1 signal increments. MSO can measure maximum of 16 digital channels User definable: 1 to 256 banks State (synchronous) or timing (asynchronous) mode
Additional information available via the Internet www.agilent.com/find/8000-altera
Ordering information
Ordering options for the Agilent N5433A FPGA dynamic probe for Altera Option 001 Option 002 * Entitlement certificate for perpetual node-locked license locked to oscilloscope (most common license type) * Entitlement certificate for PC locked license. PC and MSO must both connect to LAN. (less common license type)
Related literature
Publication title Frequently Asked Questions for Agilent MSO FPGA Dynamic Probe for Altera Agilent Technologies Infiniium 8000 series Oscilloscopes Infiniium 9000 Series Oscilloscopes Publication type Data sheet Color brochure Data sheet Publication number 5989-5957EN 5989-4271EN 5989-3746EN
Product Web site
For the most up-to-date and complete application and product information, please visit our product Web site at: www.agilent.com/find/scopes
7
Agilent Email Updates
www.agilent.com/find/emailupdates Get the latest information on the products and applications you select.
Remove all doubt
Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilenttrained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt
www.agilent.com www.agilent.com/find/altera
For more information on Agilent Technologies' products, applications or services, please contact your local Agilent office. The complete list is available at:
www.agilent.com/find/contactus Americas Canada Latin America United States Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Thailand
Agilent Direct
www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence.
(877) 894-4414 305 269 7500 (800) 829-4444
www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development.
1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 1 800 226 008
Europe & Middle East Austria 01 36027 71571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700 Germany 07031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus
Revised: October 1, 2008
Agilent Technologies Oscilloscopes
Multiple form factors from 20 MHz to >90 GHz | Industry leading specs | Powerful applications
Product specifications and descriptions in this document subject to change without notice. (c) Agilent Technologies, Inc. 2009 Printed in USA, June 12, 2009 5989-5940EN


▲Up To Search▲   

 
Price & Availability of MSO8000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X